logo

Industry Report Interpretation

TrendForce: AI Server Liquid Cooling Penetration Rate to Reach 53% in 2026, Approaching 60% in 2027

In-depth interpretation of TrendForce's latest AI Server industry research report: Liquid cooling penetration rate in AI chips will surge from 33% in 2025 to 53% in 2026 and nearly 60% in 2027. NVIDIA Vera Rubin's all-liquid cooling architecture, AMD Helios rack-level solution, and Google TPU's liquid cooling leadership drive the cold plate/CDU/manifold/QDC supply chain boom.

Report SourceTrendForce
Publication Date2026-08-17
2026 Penetration Forecast53%
2027 Penetration Forecast~60%
Content Map

Quick Navigation

This page systematically outlines the core content of TrendForce's AI server liquid cooling penetration rate report for quick reference.

Key Metrics Quick Reference

53%

2026 AI chip liquid cooling penetration rate (TrendForce forecast)

~60%

2027 AI chip liquid cooling penetration rate forecast

2,300W

NVIDIA Vera Rubin single GPU TDP (Max-P)

~230kW

Vera Rubin NVL72 full rack power consumption (Max-P)

Report Overview

1.1

Report Basic Information

ItemContent
Report NameTrendForce AI Server Industry Research Report (Liquid Cooling Thematic)
PublisherTrendForce
Publication DateAugust 17, 2026
Report CategorySemiconductor/AI Server Industry Research
Core IndicatorAI Chip Liquid Cooling Penetration Rate
1.2

Report Key Points

AI Chip Liquid Cooling Penetration Evolution (TrendForce Forecast):

YearPenetration RateKey Event
20236%AI liquid cooling pilot stage; NVIDIA H100 liquid cooling solution exploration
202414%NVIDIA GB200 NVL72 released (~120kW/rack); hybrid liquid cooling begins
202533%GB300 mass production; Tier 2 data center large-scale AI investment begins
2026E53%NVIDIA Vera Rubin all-liquid cooling architecture mass production; penetration exceeds 50%
2027E~59-60%AMD Helios large-scale shipment

Three Core Drivers

  • AI Chip Power Breaks Critical Threshold: NVIDIA, AMD, Google next-gen AI chip TDP普遍超越1kW; rack solutions reach hundreds of kW
  • Shipment Double Growth: NVIDIA GB/VR rack-level solution shipments forecast to double in 2026; GPU cabinet shipments still grow 30%+ YoY in 2027
  • CSPs Fully Following: Google over 80% of AI servers already use liquid cooling; leading CSPs extend liquid cooling from single server to full rack system design

Core Data: Liquid Cooling Penetration Evolution

2.1

Four-Year Penetration Surge

YearPenetration RateYoY Growth (percentage points)Key Event
20236%—AI liquid cooling pilot stage; NVIDIA H100 liquid cooling solution exploration
202414%+8NVIDIA GB200 NVL72 released (~120kW/rack); hybrid liquid cooling begins
202533%+19GB300 mass production; Tier 2 data center large-scale AI investment begins
2026E53%+20NVIDIA Vera Rubin all-liquid cooling architecture mass production; penetration exceeds 50%
2027E~59-60%+6~7AMD Helios large-scale shipment; Kyber NVL144 may be delayed but demand remains
2.2

China Market Penetration Comparison

YearGlobal AI Chip Liquid Cooling Penetration (TrendForce)China Liquid Cooling Server Penetration (CCID Consulting)
2021—<3%
20236%~8%
202414%~12%
202533%20%
2026E53%37%
2027E~60%>50%

Note: The two statistical scopes are different — TrendForce covers "AI chips" (GPU/TPU/ASIC), while CCID Consulting covers "liquid cooling server" shipment share.

Three Major Chip Vendors Liquid Cooling Driver Analysis

3.1

NVIDIA: From Hybrid to All-Liquid Cooling Mandatory Standard

Vera Rubin Platform: All-Liquid Cooling Mandatory Architecture

NVIDIA Vera Rubin NVL72 is the first platform with liquid cooling as a hard prerequisite:

SpecVera Rubin NVL72GB300 NVL72GB200 NVL72
GPU/CPU72 Rubin GPU + 36 Vera CPU72 Blackwell Ultra GPU + 36 Grace CPU72 Blackwell GPU + 36 Grace CPU
Single GPU TDP (Max-P)2,300W1,400W1,200W
Single GPU TDP (Max-Q)1,800W——
Rack Power (Max-P)~230kW~140kW~120kW
Rack Power (Max-Q)~190kW——
Cooling Method100% Liquid Cooling, No FansLiquid (partial air)Liquid (partial air)
Cooling Water Inlet Temp45°CStandardStandard

All-Liquid Cooling Architecture Technical Details

  • Fanless Design: Compute trays and switch trays cancel all fans; 100% relying on liquid cooling
  • Micro-channel Cold Plate: Rubin GPU cold plate internal flow channel spacing narrows from 150μm to 100μm, improving heat transfer area density
  • Liquid Metal Thermal Interface: Contact surfaces use gold plating to prevent liquid metal corrosion
  • Bus Bar Liquid Cooling: Rated current >5,000A; without fans cannot dissipate heat; must use liquid cooling
  • 45°C Warm Water Design: Can use dry coolers for natural heat dissipation, eliminating compressor chillers and achieving ultra-low PUE
3.2

AMD: From Discrete GPU to Complete AI Platform

AMD Product LineTimelineLiquid Cooling StatusPositioning
MI300X/MI3502025-2026Already using liquid coolingDiscrete GPU
Helios AI Rack-level SolutionFocus in H2 2026, mass shipment in 2027Fully adopt liquid coolingIntegrated CPU+GPU+High-speed interconnect
MI450 Platform2027Full liquid coolingHelios follow-up iteration
MI500 Platform2027+Full liquid coolingTargeting NVIDIA Rubin Ultra
3.3

Google: TPU Liquid Cooling Pioneer

Industry Leading

Google is the CSP with the strongest liquid cooling promotion; currently over 80% of AI servers use liquid cooling technology

Custom Architecture

Based on years of self-developed TPU AI accelerator and AI infrastructure integration experience, Google has established highly customized liquid cooling architecture

Industry Benchmark

Google pioneered extending liquid cooling from single servers to full rack-level system design, leading the industry by approximately 2-3 years

Liquid Cooling Technology Routes

4.1

Technology Route Overview

Cold Plate (~90% share)

  • Single-phase cold plate (mainstream)
  • Two-phase cold plate (emerging)

Immersion (~10% share)

  • Single-phase immersion
  • Two-phase immersion (phase change)

Other Solutions

  • Spray (niche/pilot)
  • Hybrid (core GPU immersion + peripheral cold plate)
4.2

Cold Plate vs Immersion Liquid Cooling

IndicatorSingle-phase Cold PlateTwo-phase Cold PlateSingle-phase ImmersionTwo-phase Immersion (Phase Change)
PUE~1.25<1.1 (Northern regions, year-round)1.1-1.21.03-1.05
Single Chip Heat Dissipation<1,200W>2,500W100kW+700-900kW
CompatibilityCompatible with existing server architectureNeeds adaptationLow (needs custom sealed chassis)Low
MaturityHigh (market mainstream)Emerging stageMediumRelatively high
4.3

Route Selection Trends

Short-term (2026-2028)

Cold plate remains market mainstream with ~90% share; compatible with existing data center retrofits, fast delivery, low operation difficulty

Medium-to-long term (2029-2031)

Two-phase immersion, hybrid solutions, and 45°C high-temperature liquid cooling gradually scale; immersion share in high-density scenarios rises to 40%

Industry Consensus: Liquid cooling industry experts judge that "80% of the market will be cold plate liquid cooling solutions in the future"; in Europe and North America with higher requirements for energy efficiency and heat recovery, immersion liquid cooling share will gradually increase.

Supply Chain and Core Components Analysis

5.1

Liquid Cooling System Architecture

Liquid Cooling System Value Chain

  • Primary Side (~25-30% value): Cooling tower/dry cooler, chiller (extreme conditions), engineering delivery; value per kW: 1.5-2k RMB
  • Secondary Side (~70-75% value): CDU (~50% of secondary side value), cold plate (micro-channel), quick disconnect coupling QDC, manifold, cooling liquid; value per kW: 3-5k RMB
5.2

Core Component Supplier Landscape

ComponentSuppliersKey Developments
Cold PlateAVC, Cooler Master, BOYD, AurasAVC holds 40-50% of NVIDIA GB200/GB300 cold plate market; Jentech is the exclusive vapor chamber supplier for Rubin platform
CDUEnvicool, Delta, VertivCDU is the "heart" of liquid cooling system; accounts for ~50% of secondary side value
ManifoldCoolIT Systems (Ecolab), Vertiv, Parker Hannifin, nVent Electric2026 market size $0.94B; 2033 forecast $6.33B; CAGR 31.2%
QDC (Quick Disconnect Coupling)Multiple suppliers competing2026 market size $1.2B; 2036 forecast $2.9B; CAGR 9.2%
5.3

Supply Chain Business Model Divergence

NVIDIA Chain

Platform strongly controls specs and certification; overseas/Taiwan suppliers have first-mover advantage; domestic companies mostly enter through OEM/OEM second supplier/whitelist certification

Google/ASIC Chain

Emphasizes supplier self-production and direct supply; large CDU outside cabinet: Envicool/Cooler Master etc.; profit elasticity better than OEM

Domestic CSP Chain

System integration and engineering delivery; relatively low certification threshold but price sensitive; benefits full-chain products + fast response + local delivery

Rack Power Density Evolution and Heat Dissipation Limits

6.1

AI Chip Power Evolution Roadmap

Chip ModelSingle Card TDPLaunch YearCooling MethodAir Cooling Feasibility
Traditional CPU<150W—Air cooling✅ Fully covered
NVIDIA H100700W2023Air cooling barely⚠️ High PUE
NVIDIA B2001,000W2024Hybrid (air + cold plate)⚠️ High operation cost
NVIDIA GB3001,400W2025Mainly liquid cooling❌ Air cooling fails
NVIDIA Rubin (Max-P)2,300W2026100% liquid cooling mandatory❌ No compromise
6.2

Rack Power Evolution

PlatformRack PowerCooling Method
Traditional server rack5-10kWAir cooling
NVIDIA GB200 NVL72~120kWLiquid (partial air)
NVIDIA GB300 NVL72~140kWLiquid (partial air)
NVIDIA Vera Rubin NVL72 (Max-P)~230kW100% liquid cooling
6.3

Server Vendor Liquid Cooling Capability Comparison

VendorSingle Rack Liquid Cooling CapabilityKey Products
Dell160kWPowerCool rear door heat exchanger; cooling energy reduced 74%; GPU density increased 4x
Supermicro362kWDLC-2 direct liquid cooling technology; scalable 3.2MW→5MW-1GW
HPE400kWFanless direct liquid cooling system
NVIDIA Reference Design230kW (Max-P)Vera Rubin NVL72; 45°C warm water

Market Size and Growth Forecast

7.1

Global Liquid Cooling Market

Forecast Source2025202620302033CAGR
Global liquid cooling market (bullish)$66B~$127B$422B$295B~20.1%
Global liquid cooling market (Soochow Securities)—$102B$873B——
Manifold market—$0.94B—$6.33B31.2%
QDC market—$1.2B—$2.9B (2036)9.2%
7.2

China Liquid Cooling Market

Indicator2021202520262030
Liquid cooling equipment market size (100M RMB)3.2557.0993.00442.13
Liquid cooling data center market size (100M RMB)——232.5—
Industry CAGR—104.78% (21-25)—47.66% (26-30)
7.3

AI Server Market Background

2026 AI Server Shipments

Global AI server shipments ~2.8M units; YoY +30.5%

AI Server Share

AI servers account for over 74% of global servers

CICC Forecast

2026 global intelligent computing center liquid cooling market 114.7B RMB; YoY +273%

Policy Drivers and Standards Progress

8.1

China Policy

New Large Data Centers

By end of 2026, liquid cooling penetration ≥60%; PUE ≤1.15

City Bans

Beijing, Shanghai and other cities have banned new air-cooled data centers

East-West Computing

Green data center strict PUE assessment; high-density intelligent computing requires PUE ≤1.1-1.15

May 2026 data: Domestic AI room liquid cooling penetration surged from 5.3% in early 2025 to 24%; high-end training cluster penetration exceeds 70%

8.2

Standardization Progress

2026 Becomes Liquid Cooling Standards Implementation Year

  • CAICT leads development of national standards for cold plate interfaces, cooling liquids, and operation specifications; 3 core standards to be released by year-end
  • Liquid cooling refrigerant standards: PG 25, EG 25, deionized water, etc. have not yet achieved unification
  • Industry pain points: interface fragmentation, poor compatibility, blurry operation responsibility boundaries

Testing Industry Insights

9.1

Liquid Cooling Equipment Testing Demand Chain

Chip-level

  • Cold plate/vapor chamber thermal performance testing
  • Contact thermal resistance measurement
  • Micro-channel flow path heat transfer efficiency
  • Liquid metal thermal interface evaluation

Component-level

  • CDU/manifold/QDC reliability testing
  • Flow and pressure distribution
  • Leak detection accuracy verification (0.1mL/min level)
  • Insertion/removal life testing (QDC: 50,000+ times)

System-level

  • Full rack heat dissipation performance verification
  • PUE actual measurement verification
  • Cooling liquid compatibility testing
  • Long-term operation reliability (5-year maintenance-free requirement)
9.2

GREENTEST Related Testing Opportunities

Testing ScenarioRelated Standards/RequirementsGREENTEST Products
CDU EMCConducted emission/radiated emissionES5500
CDU ImmunityRF electromagnetic field radiated immunityES5600
Smart liquid cooling monitoring equipment EMCIndustrial environment EMC standardsES5500 + ES5600
Liquid cooling server power system EMCInformation technology equipment standardsES5500
Immersion liquid cooling pump/valve EMCIndustrial equipment EMCES5500 + ES5600

CDU integrates pumps, heat exchangers, valves, sensors, and control systems, belonging to a typical electronic/electrical equipment combination; its EMC testing requirements highly overlap with industrial control equipment and information technology equipment.

Risks and Challenges

10.1

Technical Risks

Risk PointSpecific Description
LeakageLong-term contact of cooling liquid with metal/plastic/rubber may cause corrosion, seal aging, and plastic swelling
Interface FragmentationCold plate interfaces, cooling liquid formulas, performance indicators, and testing methods not unified; poor compatibility
Rubin Vapor Chamber IssueBaseboard warpage causes design change; two-piece → one-piece transition solution
Kyber NVL144 DelayMay be delayed in 2027, but TrendForce judges demand remains strong
10.2

Economic Risks

High Initial Investment

Cold plate single rack ~180k RMB (~30% higher than air cooling); immersion 400-500k RMB (2-3x cold plate)

Price War

Since Q2 2026, cold plate unit price dropped 20% within 3 months; gross margin fell from 30% to 15-20%

Talent Shortage

Traditional data center operation teams lack experience with liquid cooling system operations

Frequently Asked Questions (FAQ)

Q1

What is the specific statistical scope for the "53% penetration rate"?

A: TrendForce statistics cover liquid cooling penetration at the "AI chip" level, i.e., the proportion of all AI chips (GPU/TPU/ASIC) using liquid cooling. This is different from "liquid cooling server shipment share" or "liquid cooling data center count proportion."

Q2

Why will penetration jump from 33% in 2025 to 53% in 2026?

A: Mainly because NVIDIA Vera Rubin platform enters mass production in Q3 2026. Vera Rubin is the first AI platform with "no air cooling option" — 100% liquid cooling is mandatory; there is no air cooling configuration. Plus, NVIDIA GB/VR rack-level solution shipments double in 2026, adding a large number of must-have liquid cooling equipment in a single year, driving the penetration surge.

Q3

Which will become the mainstream: cold plate or immersion liquid cooling?

A: Industry consensus is that cold plate will remain mainstream for the next 3-5 years (~90% share) because it is compatible with existing data center retrofits, delivers fast, and has low operation difficulty. Immersion cooling is superior in PUE and heat dissipation limits but is constrained by construction costs and retrofit difficulty.

Q4

Why does NVIDIA Vera Rubin require 45°C warm water?

A: The 45°C inlet water temperature design allows systems to use dry coolers for natural heat dissipation without compressed chillers, significantly reducing cooling energy consumption. It also saves millions of gallons of water annually at megawatt scale while reducing cooling power consumption.

Q5

Why is Google's liquid cooling penetration rate much higher than industry average?

A: Google has developed self-made TPU AI accelerators for years and deeply integrated liquid cooling into chip design and infrastructure architecture. Google pioneered extending liquid cooling from single servers to rack-level system design. This deep customization capability gives Google AI server liquid cooling penetration over 80%, leading the industry by approximately 2-3 years.

Q6

What direct impact does liquid cooling penetration increase have on the testing industry?

A: Liquid cooling equipment is moving from validation to large-scale deployment; testing demand propagates along four levels: chip-level → component-level → system-level → facility-level. Additionally, CDU integrates pumps, valves, sensors, and control systems; its EMC testing (conducted emission/radiated emission/radiated immunity) requirements highly overlap with information technology equipment and industrial control equipment.

Q7

Does 53% penetration rate mean liquid cooling is fully普及?

A: No. 53% means about half of AI chips use liquid cooling; 47% still use air cooling or hybrid solutions. Air cooling will not disappear — traditional enterprise servers and low-density equipment can still use air cooling. Providers like AWS use "liquid + air" hybrid solutions; high-power accelerators use liquid cooling while other components still use air cooling.

Q8

Will TrendForce's 60% forecast for 2027 be affected by Kyber delay?

A: TrendForce explicitly states that although Kyber NVL144 may be delayed in 2027, AI infrastructure investment remains strong; overall GPU cabinet demand is unaffected; shipment annual growth still forecast to exceed 30%. AMD Helios platform large-scale shipment in 2027 also provides additional demand support.

Q9

What is the "micro-channel" technology in cold plate liquid cooling?

A: Micro-channel cold plate refers to fluid channel spacing inside the cold plate at micron level (e.g., Vera Rubin's cold plate channel spacing narrowed from 150μm to 100μm), greatly increasing heat transfer area per unit to improve heat dissipation efficiency.

Q10

What are the opportunities for domestic liquid cooling manufacturers going overseas?

A: According to Soochow Securities analysis, domestic liquid cooling manufacturers' overseas orders are expected to accelerate in H2 2026. Domestic liquid cooling supply chain has advantages in cost and delivery; orders from Southeast Asia, Middle East, and Europe computing projects continue to grow.

References

No.SourceLink
1TrendForce Official Newsroomhttps://www.trendforce.com/presscenter/news/20260817-13183.html
2InfoTechLeadhttps://infotechlead.com/...
3NVIDIA Developer BlogVera Rubin Architecture Analysis
4Soochow Securities Research ReportLiquid Cooling Industry Deep Report
52026 International Liquid Cooling Industry Conferencehttps://www.lctexpo.com/news/864.html

Disclaimer: This article interprets TrendForce's public report and multiple public sources. Data citations are marked with sources. Market forecasts have uncertainty; actual results may deviate from forecasts due to industry environment changes. This article does not constitute investment advice.

Explore Sales, Technical & Solution Resources?

Contact Us
Tel: 020-2204 2442
E-mail:Sales@greentest.com.cn
微信客服二维码