2026 AI chip liquid cooling penetration rate (TrendForce forecast)
Test Systems
GtestWorks Automated Testing Platform
VectWorks 3.0 Electrical Performance Test Software
In-depth interpretation of TrendForce's latest AI Server industry research report: Liquid cooling penetration rate in AI chips will surge from 33% in 2025 to 53% in 2026 and nearly 60% in 2027. NVIDIA Vera Rubin's all-liquid cooling architecture, AMD Helios rack-level solution, and Google TPU's liquid cooling leadership drive the cold plate/CDU/manifold/QDC supply chain boom.
This page systematically outlines the core content of TrendForce's AI server liquid cooling penetration rate report for quick reference.
2026 AI chip liquid cooling penetration rate (TrendForce forecast)
2027 AI chip liquid cooling penetration rate forecast
NVIDIA Vera Rubin single GPU TDP (Max-P)
Vera Rubin NVL72 full rack power consumption (Max-P)
| Item | Content |
|---|---|
| Report Name | TrendForce AI Server Industry Research Report (Liquid Cooling Thematic) |
| Publisher | TrendForce |
| Publication Date | August 17, 2026 |
| Report Category | Semiconductor/AI Server Industry Research |
| Core Indicator | AI Chip Liquid Cooling Penetration Rate |
AI Chip Liquid Cooling Penetration Evolution (TrendForce Forecast):
| Year | Penetration Rate | Key Event |
|---|---|---|
| 2023 | 6% | AI liquid cooling pilot stage; NVIDIA H100 liquid cooling solution exploration |
| 2024 | 14% | NVIDIA GB200 NVL72 released (~120kW/rack); hybrid liquid cooling begins |
| 2025 | 33% | GB300 mass production; Tier 2 data center large-scale AI investment begins |
| 2026E | 53% | NVIDIA Vera Rubin all-liquid cooling architecture mass production; penetration exceeds 50% |
| 2027E | ~59-60% | AMD Helios large-scale shipment |
| Year | Penetration Rate | YoY Growth (percentage points) | Key Event |
|---|---|---|---|
| 2023 | 6% | — | AI liquid cooling pilot stage; NVIDIA H100 liquid cooling solution exploration |
| 2024 | 14% | +8 | NVIDIA GB200 NVL72 released (~120kW/rack); hybrid liquid cooling begins |
| 2025 | 33% | +19 | GB300 mass production; Tier 2 data center large-scale AI investment begins |
| 2026E | 53% | +20 | NVIDIA Vera Rubin all-liquid cooling architecture mass production; penetration exceeds 50% |
| 2027E | ~59-60% | +6~7 | AMD Helios large-scale shipment; Kyber NVL144 may be delayed but demand remains |
| Year | Global AI Chip Liquid Cooling Penetration (TrendForce) | China Liquid Cooling Server Penetration (CCID Consulting) |
|---|---|---|
| 2021 | — | <3% |
| 2023 | 6% | ~8% |
| 2024 | 14% | ~12% |
| 2025 | 33% | 20% |
| 2026E | 53% | 37% |
| 2027E | ~60% | >50% |
Note: The two statistical scopes are different — TrendForce covers "AI chips" (GPU/TPU/ASIC), while CCID Consulting covers "liquid cooling server" shipment share.
NVIDIA Vera Rubin NVL72 is the first platform with liquid cooling as a hard prerequisite:
| Spec | Vera Rubin NVL72 | GB300 NVL72 | GB200 NVL72 |
|---|---|---|---|
| GPU/CPU | 72 Rubin GPU + 36 Vera CPU | 72 Blackwell Ultra GPU + 36 Grace CPU | 72 Blackwell GPU + 36 Grace CPU |
| Single GPU TDP (Max-P) | 2,300W | 1,400W | 1,200W |
| Single GPU TDP (Max-Q) | 1,800W | — | — |
| Rack Power (Max-P) | ~230kW | ~140kW | ~120kW |
| Rack Power (Max-Q) | ~190kW | — | — |
| Cooling Method | 100% Liquid Cooling, No Fans | Liquid (partial air) | Liquid (partial air) |
| Cooling Water Inlet Temp | 45°C | Standard | Standard |
| AMD Product Line | Timeline | Liquid Cooling Status | Positioning |
|---|---|---|---|
| MI300X/MI350 | 2025-2026 | Already using liquid cooling | Discrete GPU |
| Helios AI Rack-level Solution | Focus in H2 2026, mass shipment in 2027 | Fully adopt liquid cooling | Integrated CPU+GPU+High-speed interconnect |
| MI450 Platform | 2027 | Full liquid cooling | Helios follow-up iteration |
| MI500 Platform | 2027+ | Full liquid cooling | Targeting NVIDIA Rubin Ultra |
Google is the CSP with the strongest liquid cooling promotion; currently over 80% of AI servers use liquid cooling technology
Based on years of self-developed TPU AI accelerator and AI infrastructure integration experience, Google has established highly customized liquid cooling architecture
Google pioneered extending liquid cooling from single servers to full rack-level system design, leading the industry by approximately 2-3 years
| Indicator | Single-phase Cold Plate | Two-phase Cold Plate | Single-phase Immersion | Two-phase Immersion (Phase Change) |
|---|---|---|---|---|
| PUE | ~1.25 | <1.1 (Northern regions, year-round) | 1.1-1.2 | 1.03-1.05 |
| Single Chip Heat Dissipation | <1,200W | >2,500W | 100kW+ | 700-900kW |
| Compatibility | Compatible with existing server architecture | Needs adaptation | Low (needs custom sealed chassis) | Low |
| Maturity | High (market mainstream) | Emerging stage | Medium | Relatively high |
Cold plate remains market mainstream with ~90% share; compatible with existing data center retrofits, fast delivery, low operation difficulty
Two-phase immersion, hybrid solutions, and 45°C high-temperature liquid cooling gradually scale; immersion share in high-density scenarios rises to 40%
Industry Consensus: Liquid cooling industry experts judge that "80% of the market will be cold plate liquid cooling solutions in the future"; in Europe and North America with higher requirements for energy efficiency and heat recovery, immersion liquid cooling share will gradually increase.
| Component | Suppliers | Key Developments |
|---|---|---|
| Cold Plate | AVC, Cooler Master, BOYD, Auras | AVC holds 40-50% of NVIDIA GB200/GB300 cold plate market; Jentech is the exclusive vapor chamber supplier for Rubin platform |
| CDU | Envicool, Delta, Vertiv | CDU is the "heart" of liquid cooling system; accounts for ~50% of secondary side value |
| Manifold | CoolIT Systems (Ecolab), Vertiv, Parker Hannifin, nVent Electric | 2026 market size $0.94B; 2033 forecast $6.33B; CAGR 31.2% |
| QDC (Quick Disconnect Coupling) | Multiple suppliers competing | 2026 market size $1.2B; 2036 forecast $2.9B; CAGR 9.2% |
Platform strongly controls specs and certification; overseas/Taiwan suppliers have first-mover advantage; domestic companies mostly enter through OEM/OEM second supplier/whitelist certification
Emphasizes supplier self-production and direct supply; large CDU outside cabinet: Envicool/Cooler Master etc.; profit elasticity better than OEM
System integration and engineering delivery; relatively low certification threshold but price sensitive; benefits full-chain products + fast response + local delivery
| Chip Model | Single Card TDP | Launch Year | Cooling Method | Air Cooling Feasibility |
|---|---|---|---|---|
| Traditional CPU | <150W | — | Air cooling | ✅ Fully covered |
| NVIDIA H100 | 700W | 2023 | Air cooling barely | ⚠️ High PUE |
| NVIDIA B200 | 1,000W | 2024 | Hybrid (air + cold plate) | ⚠️ High operation cost |
| NVIDIA GB300 | 1,400W | 2025 | Mainly liquid cooling | ❌ Air cooling fails |
| NVIDIA Rubin (Max-P) | 2,300W | 2026 | 100% liquid cooling mandatory | ❌ No compromise |
| Platform | Rack Power | Cooling Method |
|---|---|---|
| Traditional server rack | 5-10kW | Air cooling |
| NVIDIA GB200 NVL72 | ~120kW | Liquid (partial air) |
| NVIDIA GB300 NVL72 | ~140kW | Liquid (partial air) |
| NVIDIA Vera Rubin NVL72 (Max-P) | ~230kW | 100% liquid cooling |
| Vendor | Single Rack Liquid Cooling Capability | Key Products |
|---|---|---|
| Dell | 160kW | PowerCool rear door heat exchanger; cooling energy reduced 74%; GPU density increased 4x |
| Supermicro | 362kW | DLC-2 direct liquid cooling technology; scalable 3.2MW→5MW-1GW |
| HPE | 400kW | Fanless direct liquid cooling system |
| NVIDIA Reference Design | 230kW (Max-P) | Vera Rubin NVL72; 45°C warm water |
| Forecast Source | 2025 | 2026 | 2030 | 2033 | CAGR |
|---|---|---|---|---|---|
| Global liquid cooling market (bullish) | $66B | ~$127B | $422B | $295B | ~20.1% |
| Global liquid cooling market (Soochow Securities) | — | $102B | $873B | — | — |
| Manifold market | — | $0.94B | — | $6.33B | 31.2% |
| QDC market | — | $1.2B | — | $2.9B (2036) | 9.2% |
| Indicator | 2021 | 2025 | 2026 | 2030 |
|---|---|---|---|---|
| Liquid cooling equipment market size (100M RMB) | 3.25 | 57.09 | 93.00 | 442.13 |
| Liquid cooling data center market size (100M RMB) | — | — | 232.5 | — |
| Industry CAGR | — | 104.78% (21-25) | — | 47.66% (26-30) |
Global AI server shipments ~2.8M units; YoY +30.5%
AI servers account for over 74% of global servers
2026 global intelligent computing center liquid cooling market 114.7B RMB; YoY +273%
By end of 2026, liquid cooling penetration ≥60%; PUE ≤1.15
Beijing, Shanghai and other cities have banned new air-cooled data centers
Green data center strict PUE assessment; high-density intelligent computing requires PUE ≤1.1-1.15
May 2026 data: Domestic AI room liquid cooling penetration surged from 5.3% in early 2025 to 24%; high-end training cluster penetration exceeds 70%
| Testing Scenario | Related Standards/Requirements | GREENTEST Products |
|---|---|---|
| CDU EMC | Conducted emission/radiated emission | ES5500 |
| CDU Immunity | RF electromagnetic field radiated immunity | ES5600 |
| Smart liquid cooling monitoring equipment EMC | Industrial environment EMC standards | ES5500 + ES5600 |
| Liquid cooling server power system EMC | Information technology equipment standards | ES5500 |
| Immersion liquid cooling pump/valve EMC | Industrial equipment EMC | ES5500 + ES5600 |
CDU integrates pumps, heat exchangers, valves, sensors, and control systems, belonging to a typical electronic/electrical equipment combination; its EMC testing requirements highly overlap with industrial control equipment and information technology equipment.
| Risk Point | Specific Description |
|---|---|
| Leakage | Long-term contact of cooling liquid with metal/plastic/rubber may cause corrosion, seal aging, and plastic swelling |
| Interface Fragmentation | Cold plate interfaces, cooling liquid formulas, performance indicators, and testing methods not unified; poor compatibility |
| Rubin Vapor Chamber Issue | Baseboard warpage causes design change; two-piece → one-piece transition solution |
| Kyber NVL144 Delay | May be delayed in 2027, but TrendForce judges demand remains strong |
Cold plate single rack ~180k RMB (~30% higher than air cooling); immersion 400-500k RMB (2-3x cold plate)
Since Q2 2026, cold plate unit price dropped 20% within 3 months; gross margin fell from 30% to 15-20%
Traditional data center operation teams lack experience with liquid cooling system operations
A: TrendForce statistics cover liquid cooling penetration at the "AI chip" level, i.e., the proportion of all AI chips (GPU/TPU/ASIC) using liquid cooling. This is different from "liquid cooling server shipment share" or "liquid cooling data center count proportion."
A: Mainly because NVIDIA Vera Rubin platform enters mass production in Q3 2026. Vera Rubin is the first AI platform with "no air cooling option" — 100% liquid cooling is mandatory; there is no air cooling configuration. Plus, NVIDIA GB/VR rack-level solution shipments double in 2026, adding a large number of must-have liquid cooling equipment in a single year, driving the penetration surge.
A: Industry consensus is that cold plate will remain mainstream for the next 3-5 years (~90% share) because it is compatible with existing data center retrofits, delivers fast, and has low operation difficulty. Immersion cooling is superior in PUE and heat dissipation limits but is constrained by construction costs and retrofit difficulty.
A: The 45°C inlet water temperature design allows systems to use dry coolers for natural heat dissipation without compressed chillers, significantly reducing cooling energy consumption. It also saves millions of gallons of water annually at megawatt scale while reducing cooling power consumption.
A: Google has developed self-made TPU AI accelerators for years and deeply integrated liquid cooling into chip design and infrastructure architecture. Google pioneered extending liquid cooling from single servers to rack-level system design. This deep customization capability gives Google AI server liquid cooling penetration over 80%, leading the industry by approximately 2-3 years.
A: Liquid cooling equipment is moving from validation to large-scale deployment; testing demand propagates along four levels: chip-level → component-level → system-level → facility-level. Additionally, CDU integrates pumps, valves, sensors, and control systems; its EMC testing (conducted emission/radiated emission/radiated immunity) requirements highly overlap with information technology equipment and industrial control equipment.
A: No. 53% means about half of AI chips use liquid cooling; 47% still use air cooling or hybrid solutions. Air cooling will not disappear — traditional enterprise servers and low-density equipment can still use air cooling. Providers like AWS use "liquid + air" hybrid solutions; high-power accelerators use liquid cooling while other components still use air cooling.
A: TrendForce explicitly states that although Kyber NVL144 may be delayed in 2027, AI infrastructure investment remains strong; overall GPU cabinet demand is unaffected; shipment annual growth still forecast to exceed 30%. AMD Helios platform large-scale shipment in 2027 also provides additional demand support.
A: Micro-channel cold plate refers to fluid channel spacing inside the cold plate at micron level (e.g., Vera Rubin's cold plate channel spacing narrowed from 150μm to 100μm), greatly increasing heat transfer area per unit to improve heat dissipation efficiency.
A: According to Soochow Securities analysis, domestic liquid cooling manufacturers' overseas orders are expected to accelerate in H2 2026. Domestic liquid cooling supply chain has advantages in cost and delivery; orders from Southeast Asia, Middle East, and Europe computing projects continue to grow.
| No. | Source | Link |
|---|---|---|
| 1 | TrendForce Official Newsroom | https://www.trendforce.com/presscenter/news/20260817-13183.html |
| 2 | InfoTechLead | https://infotechlead.com/... |
| 3 | NVIDIA Developer Blog | Vera Rubin Architecture Analysis |
| 4 | Soochow Securities Research Report | Liquid Cooling Industry Deep Report |
| 5 | 2026 International Liquid Cooling Industry Conference | https://www.lctexpo.com/news/864.html |
Disclaimer: This article interprets TrendForce's public report and multiple public sources. Data citations are marked with sources. Market forecasts have uncertainty; actual results may deviate from forecasts due to industry environment changes. This article does not constitute investment advice.